EDP Sciences Journals List
Advanced Search

Free access article

Issue Analusis
Volume 26, Number 10, December 1998
MALDI-TOF
Page(s) 381 - 388
Section Original articles
DOI http://dx.doi.org/10.1051/analusis:1998189

Analusis 26, 381-388 (1998)
DOI: 10.1051/analusis:1998189

Speciation of trace amounts of aluminium in environmental samples by cation-exchange FPLC - ETAAS

B. Mitrovic1, R. Milacic1, B. Pihlar2 and P. Simoncic3

1  Department of Environmental Sciences, Jozef Stefan Institute, 1000 Ljubljana, Slovenia
2  Faculty of Chemistry and Chemical Technology, University of Ljubljana, Askerceva 5, 1000 Ljubljana, Slovenia
3  Institute for Forestry, Vecna pot 2, 1000 Ljubljana, Slovenia


Abstract
Cation-exchange fast protein liquid chromatography - electrothermal atomic absorption spectrometry (FPLC - ETAAS) was applied for the speciation of trace amounts of aluminium. An aqueous 8 mol dm-3 NH4NO3 linear gradient elution in 10 minutes enabled separation of positively charged monomeric aluminium species in aqueous solution. Separated aluminium species were collected in 0.5 cm3 fractions and aluminium determined "off line" after fourfold dilution by ETAAS. The ability of NH4NO3 to completely decompose at low temperature in the graphite tube during the ashing step enabled quantitative and reproducible determination of aluminium. After applying Chelex-100 resin in a cleaning procedure of the eluent, the eluent blank was very low (< 1.0 ng cm-3 Al). When 1 cm3 of sample was injected on the column resin, the limit of detection (3 s) for the separated aluminium species determined by ETAAS was found to be 3 ng cm-3. Good repeatability of measurement of separated aluminium species (relative standard deviation $\pm 5\%$) was obtained under the recommended analytical conditions. The influence of some inorganic and organic complexing ligands at pH values of 4.0 and 6.0 on the speciation of aluminium was also investigated. The method developed was successfully applied for the speciation of aluminium in soil extracts and natural water samples at ng cm-3 levels.


Key words: Speciation of trace amounts of aluminium / fast protein liquid chromatography-electrothermal atomic absorption spectrometry / soil extracts / natural waters.


© EDP Sciences, Wiley-VCH 1998

What is OpenURL?

The OpenURL standard is a protocol for transmission of metadata describing the resource that you wish to access. An OpenURL link contains article metadata and directs it to the OpenURL server of your choice. The OpenURL server can provide access to the resource and also offer complementary services (specific search engine, export of references...). The OpenURL link can be generated by different means.
  • If your librarian has set up your subscription with an OpenURL resolver, OpenURL links appear automatically on the abstract pages.
  • You can define your own OpenURL resolver with your EDPS Account. In this case your choice will be given priority over that of your library.
  • You can use an add-on for your browser (Firefox or I.E.) to display OpenURL links on a page (see http://www.openly.com/openurlref/). You should disable this module if you wish to use the OpenURL server that you or your library have defined.